PID Temperature Controllers

PID Temperature Controllers features dual displays & selectable inputs. These PID Temperature Controllers are easy to operate and the out can be ordered for a relay contact, a voltage pulse, or a 4 to 20 mAmp output.

PID Temperature Controllers also excepts various inputs from f thermocouples, RTD, DC voltage and DC current. In addition these controllers can have 2 independent alarm contacts that are programmable to be deviation, process, or set value alarms.

The Heater break alarms utilize an external current transformer that monitors the heater current and activates an alarm should the current fall below a threshold value that has been set by the operator. The loop break monitors and protects the entire temperature control system.

The loop break alarm will detect Heater Breaks, Thermocouple or RTD failure, short circuits, or the failure of an operating device such as a mechanical relay, Mercury Relay or SSR.


PID Temperature Controllers Features:

Standard inputs thermocouple, RTD
Heat/Cool action

Relay, Triac, DC voltage pulse or current output

Heater break alarm for monitoring multiple parallel heaters

Loop break alarm for heater breaks/shorted sensors or relays

PID Temperature Controllers Specifications

Input
Thermocouple. . . . . . . . .K,J,R,S,B,T,L,N,E,PLII W5Re/W26Re.
RTD. . . . . . . . . . . . . (PIIOO,JPll OO) -199.9-649.0C -199.9-999 OF
DC voltage. . . . . . . . . .(0-5V,1-5V) 0.0-100%(fixed)
DC current. . . . . . . . . .(0-20mA, 4-20mA) 0.0-100%(fixed)

Control Output
Relay. . . . . . . . . . . . 25OVAC, 3A Form A or Form C contact
Voltage pulse. . . . . . . . 0/l2VDC, load resistance more than 600 Ohms
Current. . . . . . . . . . . 4-20mA DC load resistance less tham 600 Ohms

HBA Alarm
Input. . . . . . . . . . . . Output signal from CT
Range. . . . . . . . . . . . 0-30A or 0-100A
Accuracy. . . . . . . . . . .+/-0.5% or 2A whichever is larger
Relay output. . . . . . . . .25OVAC,1 A contact
Heating load draw:. . . . . .30 or 100 amps must be specified

LBA Alarm
Setting range 0.1-200.0 minutes.
Relay output 25OVAC,1 A contact

Control Action
a) PID action with autotuning
b) Heat/cool PID action with autotuning (not available on REX-C100)
Heating proportional band(P). 1-100% of input range.
Cooling proportional band. . .1-1000% of heating proportional band
Integral(1). . . . . . . . . .1-3600 seconds
Derivative(D). . . . . . . . .1-3600 seconds
ARW. . . . . . . . . . . . . .1-100% of proportional band
Heating cycle. . . . . . . . .1-100 seconds
Cooling cycle. . . . . . . . .1-100 seconds

Sampling Rate 0.5 seconds
Setting Accuracy Thermocouple input.+/-(0.5% of SV + 1 digit)

RTD input. . . . . . . . . . . +/-(0.5% of SV + 1 digit) 0.8C(1.6F)

External Dimensions
REX-C100. . . . . . . . . . . .48 x 48 x 100mm
REX-C400. . . . . . . . . . . .96 x 48 x 100mm
REX-C410. . . . . . . . . . . .48 x 96 x 100mm
REX-C700. . . . . . . . . . . .96 x 96 x 100mm

Supply Voltage 90-264VAC (50/6OHZ)