Flanged
Immersion Heaters are used in large capacity vessels,
for high temperature and pressure applications.
Flanged Immersion Heaters
are installed by bolting the unit to a matching flange
welded to the vessel. Watt densities from 90 Watts/sq
inch, Explosion Proof (NEMA 7), Corrosion Resistant
(NEMA 4X), General Purpose and Standoff Terminal housings
are available. A number of sheath materials like Titanium,
Incoloy, Stainless Steel, Steel, and Copper can be
used as required for specific applications.
Standard Flanged
Immersion Heaters
have a 150 lbs flanges but 300 lbs flanges are also
available. To guarantee sheath material and watt density
compatibility with material or process being heated
consult HCS.
Flanged Immersion Heaters Features:
•
High watt densities,
wattage's in smaller areas
• Passivated 316 stainless steel option
• Sheath temperatures to 1200ºF
• Low watt densities possible for delicate
applications
• ANSI flanges from 2" to 24"
• High pressure flanges 300 lbs
• Applications solids, liquids, gases.
Flanged
Immersion Heaters Specifications / Options
Voltages. . . . . . .
. . . . . . .120 to 600 Volts Single or Three Phase
Wattage's. . . . . . . . . . . . . Varied from 150 watts
to 1 Megawatt
Sheath Materials. . . . . . . . Titanium, Monel, Incoloy,
316/304 Stainless,
Steel Copper, Carbon Steel
Max Temperatures. . . . . . . Incoloy 1600 degrees F
(870 C)
304 / 316 Stainless Steel 1200 degrees F (650)
Steel 750 degrees F (400 C)
Copper 350 degree F (175 C)
Flanges. . . . . . . . . . . . . . ANSI or ASA 2, 21
/2, 3 4, 5, 6, 8,10,12,14,
16,18, 20, 24, or over 24 consult HCS
Pressure Rating. . . . . . . . . 150, 300 or 600 Ibs
Flange Materials. . . . . . . . .Standard Carbon Steel
or 316/304 Stainless
Gaskets. . . . . . . . . . . . . . Rubber, Asbestos
Free, or Spiral wound
Terminal Enclosures. . . . . . General Purpose (NEMA
1 ),
Moisture Resistant (NEMA 4),
Corrosion
Resistant (NEMA 4X),
Explosion Resistant (NEMA 7),
Explosion Moisture Resistant (NEMA 7/4)
Temperature control. . . . . .Thermocouple, RTD, or
Thermostat
High Limit. . . . . . . . . . . . . High Limit Thermocouple,
Hi Limit Tstat,
Approvals. . . . . . . . . . . . ..CSA, UL
Certification. . . . . . . . . . . .ASME, CRR
For
Quick Delivery
From Stock Call
CANADA
& USA TOLL FREE: 1 - 800 - 279-9912
|