Field,Selectable,Input,Output,Controller

Field Selectable Input/Output Controller



Canada & USA Toll Free
1 800 279-9912
 
Field Selectable Input/Output Controller from Heaters Controls And Sensors

Field Selectable Input/Output Controller features universal field selectable outputs for the main control output. The main control output can be selected from a relay contact, a voltage pulse, or a 4 to 20 mAmp output.

Field Selectable Input/Output Controller also excepts 44 types of thermocouple, RTD, DC voltage and DC current. In addition these controllers can have 2 independent alarm contacts that are programmable to be deviation, process, or set value alarms. The Heater break alarms utilize an external current transformer that monitors the heater current and activates an alarm should the current fall below a threshold value that has been set by the operator. The loop break monitors and protects the entire temperature control system. The loop break alarm will detect Heater Breaks, Thermocouple or RTD failure, short circuits, or the failure of an operating device such as a mechanical relay, Mercury Relay or SSR.


Field Selectable Input/Output Controller Features:

Standard universal inputs
Field selectable outputs
Easy set up and programming fuzzy logic on/off
Heater break alarm for monitoring multiple parallel heaters
Loop break alarm for heater breaks/shorted sensors or relays
Alarm hold and alarm delay functions 2 alarms field configurable
Dual set point local or remote setable and ramp to setpoint

Field Selectable Input/Output Controller Specifications

Input
Universal Field Selectable

Thermocouples. . . . . . (K,J,T,E,R,B,N,S,L,U)
RTD. . . . . . . . . . . PT100, JPT 100
Millivolts. . . . . . . .0-lOmV, 0-100mV, 0-1V, 0-5V,1-5V, 0-10V
Current. . . . . . . . . 4-20mA DC 0-20mA DC
Default setting. . . . . -300 to 1500F J

Control output
Universal Field Selectable

Relay output. . . . . . .(25OVAC, 3A resistive load)
Voltage pulse output. . .(0/l2VDC)
Current output. . . . . .(0-20mA DC, 4-20mA DC,max 600 ohms)
Continuos voltageA. . . .(0-5V, 0-1 OV,1-5V, DC Load Res > 1 K )

ALARM
Maximum two alarms (independent setting)

Alarm type. . . . . . . .programmable (process or deviation)
Alarm output. . . . . . .relay output.

Control Method
P, PI,PD,PID with fuzzy, on/off
Error output 0:.........output off or 0% 1:.........output on or 100%
Output errors mean T/C, RTD input disconnection,A/D convertor error 
and setting data error. Accuracy. . . . . . . . .+/-0.3%FS+1 digit Sampling time. . . . . . 0.5 second(500ms) External Dimensions REX- D100. . . . . . . . 48 x 48 x 100mm REX- D400. . . . . . . . 96 x 48 x 100mm REX- D900. . . . . . . . 96 x 96 x 100mm Power Supply. . . . . . .90 - 264 VAC - 50/60 Hz 6VA 100V, 9VA 200v OPTIONS Digital communication. . RS-485 (2 wire type) RS-422A (4 wire type) Communication speed. . . 150,300,1200,2400,4800,9600 bps. Address. . . . . . . . . 1 to 16 Parit. . . . . . . . . . with or without, even or odd in case of with Stop bit. . . . . . . . .1 or 2 Data bit. . . . . . . . .7 or 8 External contact signal Off (SP1 ) On (SP2) Retransmission output. . 4-20mA DC, 0-20mA DC,1-5VDC,O-1 OVDC,O-5VDC

 